Attach
Place the magnetic sensor on the bearing housing and connect USB-C to a phone or computer.
Developed by VibeDynamics and made in the Czech Republic, VIBE ANALYZER combines our own hardware and diagnostic software. Service is included. We deliver worldwide and provide manufacturer support. The same hardware can be upgraded to the balancing edition later.
Buying guide → · Try the app demo → · Android app on Google Play → · Technický list CZ (PDF)

Place the magnetic sensor on the bearing housing and connect USB-C to a phone or computer.
Select the measurement and press START. Standard captures are 1, 2, 4 or 8 seconds.
Read the condition and recommendation, then save a PDF report or open the detailed spectra.
Values from the datasheet. The full datasheet is available as a PDF.
Identify points, assign bearings, set ISO or custom limits and build trends over time.
Envelope analysis plus a 30,000+ bearing database for BPFO/BPFI/BSF/FTF matching.
Acceleration, velocity, displacement, time signal, FFT, envelope and waterfall tools.
A ready PDF with condition, detected patterns and recommendations straight after measurement.
HTTP/API options for connecting measurement data to maintenance systems and workflows.
Ten specialist evaluations are included; optional Cloud Expert supports ongoing use.
The PDF report is created right after the measurement, with no extra software.
| Freq. | Theor. | Detected | |
|---|---|---|---|
| BPFI | 77.6 Hz | 2×–10× | Confirmed 80% |
| BPFO | 53.9 Hz | 1×–10× | Confirmed 79% |
| BSF | 35.4 Hz | 3×–9× | Confirmed 77% |
| FTF | 5.39 Hz | — | No match |
Recommendation: Bearing replacement recommended. Phase 4 — advanced damage. Until then shorten the monitoring interval to 3 days.

The interface is available for Android and Windows. Route data and measurements can be moved between devices.
We will measure your most troublesome machine and show you the result on your own data before you decide anything.